EANCOM® 2002 S3 Edition 2016 Part II
CONDRA Drawing administration message
5. Segments Layout
 
Previous Segment Segment number: 8 Legend Next Segment
SG5 - C 99 -
EFI-CED-RFF-DTM-QTY
A group of segments that refers through an external file identification to each of the external engineering/CAD files and giving additional information about each of the files.
EFI - M 1 -
External file link identification
  Function:
  To specify the link of one non-EDIFACT external file to an EDIFACT message.
 
EDIFACT
EAN *
Description
C077
FILE IDENTIFICATION
M
M    
1508
File name
C an..35
R  
External Object Identification
This data element is used to provide the external object's identification.
7008
Item description
C an..256
O    
C099
FILE DETAILS
C
R    
1516
File format name
M an..17
M  
This data element is used to describe the format of the external object. If the object is a computer file the format may be BMP, PCX. If the external object is a video, the format may be SECAM, PAL, etc... If the object is in a physical form such as paper or transparancies, this data element should be filled with "OTHER".
1056
Version identifier
C an..9
N    
1503
Data format description code
C an..3
R  
3 = Binary
4 = Analogue
1502
Data format description
C an..35
N    
1050
Sequence position identifier
C an..10
O  
Sequence number on the physical medium
9450
File compression technique name
C an..35
N    
Segment Notes:
This segment is used to identify an external object by indicating its identification, the format, and its sequence number on the physical medium.

Example:
EFI+ECRSTRUC+BMP::3'
The object is a binary file named ECRSTRUC.
Previous Segment Next Segment