EANCOM® 2002 S4 Edition 2016 Part II
QALITY Quality data message
5. Segments Layout
 
Previous Segment Segment number: 15 Legend Next Segment
SG5 - C 200 -
LIN-PIA-IMD-MEA-DTM-QTY-FTX-SG6-SG7-SG12
A group of segments providing the relevant quality data for the specified product.
MEA - C 10 -
Measurements
  Function:
  To specify physical measurements, including dimension tolerances, weights and counts.
 
EDIFACT
EAN *
Description
6311
Measurement purpose code qualifier
M an..3
M  
PD = Physical dimensions (product ordered)
SV = Specification value
C502
MEASUREMENT DETAILS
C
A    
6313
Measured attribute code
C an..3
A  
AAU = Operative temperature
DI = Diameter
LN = Length dimension
6321
Measurement significance code
C an..3
O  
3 = Approximately
4 = Equal to
6155
Non-discrete measurement name code
C an..17
O    
6154
Non-discrete measurement name
C an..70
O    
C174
VALUE/RANGE
C
R    
6411
Measurement unit code
M an..3
M  
CEL = degree celsius
FAH = degree Fahrenheit
MMT = millimetre
VLT = volt
6314
Measurement value
C an..18
O    
6162
Range minimum value
C n..18
O    
6152
Range maximum value
C n..18
O    
6432
Significant digits quantity
C n..2
N    
7383
Surface or layer code
C an..3
N    
Segment Notes:
This segment is used to specify measurements relative to the item which has been tested, e.g. the weight of the item tested,  range of temperatures which a meter should cater for,  etc.

Example:
MEA+SV+AAU+CEL::20:150'
The current item has a specification value in the range of 20 to 150 degrees celsius.
Previous Segment Next Segment
© Copyright GS1 Edition 2016