EANCOM® 2002 S4 Edition 2016 Part II
QALITY Quality data message
5. Segments Layout
 
Previous Segment Segment number: 14 Legend Next Segment
SG5 - C 200 -
LIN-PIA-IMD-MEA-DTM-QTY-FTX-SG6-SG7-SG12
A group of segments providing the relevant quality data for the specified product.
IMD - C 10 -
Item description
  Function:
  To describe an item in either an industry or free format.
 
EDIFACT
EAN *
Description
7077
Description format code
C an..3
O *
General explanations
C = Code (from industry code list)
F = Free-form
B = Code and text
C272
ITEM CHARACTERISTIC
C
O    
7081
Item characteristic code
C an..3
R    
1131
Code list identification code
C an..17
O    
3055
Code list responsible agency code
C an..3
D *
General explanations
9 = GS1
Must be used if DE7081 contains an GS1 code.
C273
ITEM DESCRIPTION
C
A    
7009
Item description code
C an..17
O  
CU = Consumer unit (GS1 Permanent Code)
DU = Despatch unit (GS1 Permanent Code)
TU = Traded unit (GS1 Permanent Code)
1131
Code list identification code
C an..17
O    
3055
Code list responsible agency code
C an..3
D  
9 = GS1
7008
Item description
C an..256
O    
7008
Item description
C an..256
O    
3453
Language name code
C an..3
O    
7383
Surface or layer code
C an..3
N    
Segment Notes:
This segment is used to describe the item for which test results are being provided. This segment should only be used for items that cannot be fully identified by a GTIN.

Example:
IMD+F++:::SIEMENS METER:ALL SERVICES'
The item tested was an All Services Siemens Meter.
Previous Segment Next Segment
© Copyright GS1 Edition 2016