EANCOM® 2002 S3 Edition 2016 Part II
MSCONS Metered services consumption report message
5. Segments Layout
 
Previous Segment Segment number: 29 Legend Next Segment
CNT - C 99 -
Control total
  Function:
  To provide control total.
 
EDIFACT
EAN *
Description
C270
CONTROL
M
M    
6069
Control total type code qualifier
M an..3
M *
General explanations
31E = Number of premises (GS1 CTemporary ode)
36E = Number of meters (GS1 Temporary Code)
6066
Control total value
M n..18
M  
When using code '31E' this figure is calculated by counting the total number of NAD segments in segment group 5. When using code '36E' this figure is calculated by counting the total number of meters in segment group 6.
6411
Measurement unit code
C an..3
O    
Segment Notes:
This is used to provide message control information for checking on the message receivers in-house system.

Example:
CNT+36E:45'
Previous Segment Next Segment
© Copyright GS1 Edition 2016