EANCOM® 2002 S3 Edition 2016 Part II
MSCONS Metered services consumption report message
5. Segments Layout
 
Previous Segment Segment number: 27 Legend Next Segment
SG5 - M 99999 -
NAD-SG6
A group of segments identifying the delivery party (premise) and the meter for which consumption is being reported. This segment group is the trigger segment group to the detail section of the message and must be included at least once.
SG6 - M 99999 -
LOC-DTM-SG7-SG8-SG9
A group of segments identifying the meter being reported, the date of the meter read, associated references, the physical characteristics of the meter, and the product or service for which consumption information is being reported.
SG9 - C 99999 -
LIN-PIA-IMD-PRI-NAD-MOA-SG10-SG11
A group of segments providing details of the metered products or services, quantities, characteristics, and any associated dates.
SG11 - C 99 -
CCI-MEA-DTM
A group of segments providing characteristic details, measurements, and dates related to the details for the currently identified line item.
MEA - C 99 -
Measurements
  Function:
  To specify physical measurements, including dimension tolerances, weights and counts.
 
EDIFACT
EAN *
Description
6311
Measurement purpose code qualifier
M an..3
M  
SV = Specification value
CT = Counts
DV = Discrete measurement value
VO = Observed value (GS1 Temporary Code)
VT = True value (GS1 Temporary Code)
C502
MEASUREMENT DETAILS
C
O    
6313
Measured attribute code
C an..3
A  
AAP = Voltage
AAQ = Power consumption
AAR = Heat dissipation
AAY = Water content
ABJ = Volume
TC = Temperature
ZWA = Waste content
6321
Measurement significance code
C an..3
O  
3 = Approximately
4 = Equal to
6155
Non-discrete measurement name code
C an..17
O    
6154
Non-discrete measurement name
C an..70
N    
C174
VALUE/RANGE
C
R    
6411
Measurement unit code
M an..3
M  
GV = gigajoule
GLI = gallon (UK)
GWH = gigawatt hour
KHZ = kilohertz
KJO = kilojoule
KVT = kilovolt
KWH = kilowatt hour
VLT = volt
CMT = centimetre
MTQ = cubic metre
H87 = Piece
E10 = Degree day
E11 = Gigacalorie
JM = Megajoule per cubic metre
6314
Measurement value
C an..18
O    
6162
Range minimum value
C n..18
O    
6152
Range maximum value
C n..18
O    
6432
Significant digits quantity
C n..2
O    
7383
Surface or layer code
C an..3
N    
Segment Notes:
This segment is used to specify any measurements related to the currently identified product characteristic class and to provide measurements relevant to the characteristics provided for all the reported services (products) in one location.

Example:
MEA+SV+AAP+VLT:2000'

MEA+VO+ABJ+MTQ:12'
Previous Segment Next Segment
© Copyright GS1 Edition 2016