EANCOM® 2002 S3 Edition 2016 Part II
MSCONS Metered services consumption report message
5. Segments Layout
 
Previous Segment Segment number: 13 Legend Next Segment
SG5 - M 99999 -
NAD-SG6
A group of segments identifying the delivery party (premise) and the meter for which consumption is being reported. This segment group is the trigger segment group to the detail section of the message and must be included at least once.
SG6 - M 99999 -
LOC-DTM-SG7-SG8-SG9
A group of segments identifying the meter being reported, the date of the meter read, associated references, the physical characteristics of the meter, and the product or service for which consumption information is being reported.
DTM - C 9 -
Date/time/period
  Function:
  To specify date, and/or time, or period.
 
EDIFACT
EAN *
Description
C507
DATE/TIME/PERIOD
M
M    
2005
Date or time or period function code qualifier
M an..3
M *
General explanations
263 = Invoicing period
273 = Validity period
367 = Previous meter reading date
368 = Latest meter reading date
2380
Date or time or period value
C an..35
R    
2379
Date or time or period format code
C an..3
R  
102 = CCYYMMDD
203 = CCYYMMDDHHMM
718 = CCYYMMDD-CCYYMMDD
Segment Notes:
This segment is used to specify any dates associated with the meter identified in the LOC segment.

Example:
DTM+367:20020104:102'
Previous Segment Next Segment
© Copyright GS1 Edition 2016