EANCOM® 2002 S4 Edition 2016 Part II
QALITY Quality data message
5. Segments Layout
 
Previous Segment Segment number: 5 Legend Next Segment
SG1 - C 10 -
RFF-DTM
A segment group for referencing documents and where necessary, their dates, relating to the whole message, e.g. purchase order, shipment/consignment number.
RFF - M 1 -
Reference
  Function:
  To specify a reference.
 
EDIFACT
EAN *
Description
C506
REFERENCE
M
M    
1153
Reference code qualifier
M an..3
M *
General explanations
ADD = Analysis number/test number
TP = Test report number
TS = Test specification number (GS1 Temporary Code)
The code value 'TP' should only be used in this segment when code value '5, Replacement' has been used in data element 1225 of the BGM segment.
The code value 'TS' is used to indicate a test specification provided by the party ordering the test which has been used during the testing process.
1154
Reference identifier
C an..70
R    
1156
Document line identifier
C an..6
N    
4000
Reference version identifier
C an..35
N    
1060
Revision identifier
C an..6
N    
Segment Notes:
This segment is used to identify any references which relate to the complete quality test report.

Example:
RFF+ADD:123456'
Previous Segment Next Segment
© Copyright GS1 Edition 2016