EANCOM® 2002 S4 Edition 2016 Part II
QALITY Quality data message
5. Segments Layout
 
Previous Segment Segment number: 17 Legend Next Segment
SG5 - C 200 -
LIN-PIA-IMD-MEA-DTM-QTY-FTX-SG6-SG7-SG12
A group of segments providing the relevant quality data for the specified product.
QTY - C 99 -
Quantity
  Function:
  To specify a pertinent quantity.
 
EDIFACT
EAN *
Description
C186
QUANTITY DETAILS
M
M    
6063
Quantity type code qualifier
M an..3
M *
General explanations
74 = Latest cumulative quantity
79 = Previous cumulative quantity
99 = Estimated quantity
40E = Quantity tested (GS1 Temporary Code)
6060
Quantity
M an..35
M    
6411
Measurement unit code
C an..3
D  
KGM = kilogram
MTQ = cubic metre
MWH = megawatt hour (1000 kW.h)
This DE is only used if the product which was tested is a variable quantity product.
Segment Notes:
This segment is used to indicate the quantity tested for the current line item.

Example:
QTY+40E:400'
Previous Segment Next Segment
© Copyright GS1 Edition 2016