EANCOM® 2002 S4 Edition 2016 Part II
MSCONS Metered services consumption report message
5. Segments Layout
 
Previous Segment Segment number: 14 Legend Next Segment
SG5 - M 99999 -
NAD-SG6
A group of segments identifying the delivery party (premise) and the meter for which consumption is being reported. This segment group is the trigger segment group to the detail section of the message and must be included at least once.
SG6 - M 99999 -
LOC-DTM-SG7-SG8-SG9
A group of segments identifying the meter being reported, the date of the meter read, associated references, the physical characteristics of the meter, and the product or service for which consumption information is being reported.
SG7 - C 99 -
RFF-DTM
A group of segments for specifying any references and associated dates valid for the meter identified in the LOC segment.
RFF - M 1 -
Reference
  Function:
  To specify a reference.
 
EDIFACT
EAN *
Description
C506
REFERENCE
M
M    
1153
Reference code qualifier
M an..3
M  
MSC = Metered services consumption report (GS1 Temporary Code)
ON = Order number (buyer)
SE = Serial number
1154
Reference identifier
C an..70
R    
1156
Document line identifier
C an..6
O    
4000
Reference version identifier
C an..35
N    
1060
Revision identifier
C an..6
N    
Segment Notes:
This segment is used to identify any references associated with the currently identified meter. References provided here which use the same qualifier as that used in the RFF segment in the heading section will override the reference provided in the heading section for this meter only.

Example:
RFF+SE:2015ACX'
This reference identifies the serial number 2015ACX of the current meter.
Previous Segment Next Segment
© Copyright GS1 Edition 2016