EANCOM® 2002 S4 Edition 2016 Part II
INSDES Instruction to despatch message
5. Segments Layout
 
Previous Segment Segment number: 25 Legend Next Segment
SG10 - C 9999 -
LIN-PIA-IMD-QTY-GIN-DTM-FTX-MOA-SG11-SG12-SG13
A group of segments providing details of individual line items for which Instruction to Despatch message information is being provided.
SG11 - C 9 -
RFF-DTM
A group of segments to give reference numbers and dates related to the current line item.
RFF - M 1 -
Reference
  Function:
  To specify a reference.
 
EDIFACT
EAN *
Description
C506
REFERENCE
M
M    
1153
Reference code qualifier
M an..3
M  
AAJ = Delivery order number
AAN = Delivery schedule number
CT = Contract number
HN = Handling and movement reference number (GS1 Temporary Code)
IP = Import licence number
ON = Order number (buyer)
1154
Reference identifier
C an..70
R    
1156
Document line identifier
C an..6
O    
4000
Reference version identifier
C an..35
N    
1060
Revision identifier
C an..6
N    
Segment Notes:
This segment is used to specify any references which apply to the current line item only.  References provided here override those provided in the heading section of the message when the same qualifier is used.

Example:
RFF+CT:CT051523'
Previous Segment Next Segment
© Copyright GS1 Edition 2016